Strip Test Database
STRIP15 – Bandpass characterization Tcryo (PS0101 - PWR3 blind)
General information
Polarimeter | STRIP15 |
Acquisition date | |
Band | Q |
Cryogenic? | Yes |
Operators | Claudio Pincella |
Description | Bandpass characterization Tcryo (PS0101 - PWR3 blind) |
PHSW state | 0101 |
Notes | The source data file was «SCI170329_111614 - Qband15_Tcryo20K_RF -40dBm_0101_caso4_+++pari_H4conVg=100mV_29March2017.txt» (411 kB) |
Author | claudio |
Date of creation | |
JSON record | Link |
- Download data file (87.8 KB)
HEMT biases
HEMT | Vd [V] | Id [mA] | Vg [mV] |
---|---|---|---|
H0 (HA1) | 0.9 | 4.4 | -200.0 |
H1 (HB1) | 0.9 | 4.6 | 210.0 |
H2 (HA2) | 0.9 | 5.5 | 260.0 |
H3 (HB2) | 0.9 | 9.5 | 440.0 |
H4 (HA3) | 0.9 | 7.2 | 100.0 |
H5 (HB3) | 0.9 | 7.4 | 77.0 |