Strip Test Database

STRIP35 – Bandpass characterization

General information

Edit  Delete

Polarimeter STRIP35
Acquisition date
BandQ
Cryogenic?Yes
OperatorsPaola Battaglia, Claudio Pincella
PHSW state0110
Notes

The source data file was «SCI171122_100739 - STRIP35_Tcryo20K_RF_-40dBm_0110_Pol-Strip_var1_22Nov2017.txt» (439 kB)

Authorsilvia
Date of creation
JSON recordLink
ADC offsets
PWR0 PWR1 PWR2 PWR3
1802 1788 1812 1799 Edit  Delete
Detector outputs
PWR0 PWR1 PWR2 PWR3
121050 118920 117950 122830 Edit  Delete
HEMT biases
HEMT Vd [V] Id [mA] Vg [mV]
H0 (HA1) 0.9 6.15 148.0
H1 (HB1) 0.9 5.9 48.0
H2 (HA2) 0.9 5.9 461.0
H3 (HB2) 0.9 2.0 362.0
H4 (HA3) 0.9 9.34 -200.0
H5 (HB3) 0.9 6.87 202.0

Reports

Noise temperatures
Bandpasses
Method Central frequency Bandwidth Details Report Actions
43.33±0.18 6.51±0.33 JSON Download Edit  Delete
Spectrum